Product Series
Product information
Contact HAITIMA for product selection and availability.
Product Overview
Please contact HAITIMA for details.
Key Features
Please contact HAITIMA for details.
Models and Specifications
Please contact HAITIMA for details.
Performance Curves
Please contact HAITIMA for details.
Dimensions
Please contact HAITIMA for details.
Downloads
Please contact HAITIMA for details.
Submersible Pumps
Submersible Pumps
Contact HAITIMA for product information and selection assistance.
Product Series
Product information
Contact HAITIMA for product selection and availability.
Product Overview
Please contact HAITIMA for details.
Key Features
Please contact HAITIMA for details.
Models and Specifications
Please contact HAITIMA for details.
Performance Curves
Please contact HAITIMA for details.
Dimensions
Please contact HAITIMA for details.
Downloads
Please contact HAITIMA for details.
Submersible Motors
Submersible Motors
Contact HAITIMA for product information and selection assistance.
Our integrated electronic booster pumps provide steady water pressure for homes, gardens and light commercial applications.
Booster Pump Applications
HQE Series | All-in-One Electronic Booster Pump

Dual sensing and integrated electronic control help maintain a steady water supply.
The HAITIMA HQE combines a pump, motor, diaphragm tank, pressure and flow sensors, electronic control board and check valve in a compact unit for everyday water pressure boosting.
- Dual-Sensor Control — Pressure and flow sensing help the pump respond to actual water demand.
- Integrated Design — Pump and control components fit into a compact housing.
- Easy Maintenance — Modular construction simplifies routine servicing and inspection.
-
Low-Noise Operation — A centrifugal impeller helps keep operating noise low.
- Self-Priming Suction Lift — 6 m
HQE Key Features
Core Sensing and Control Technology
Integrated electronic control helps the booster pump respond to water demand, supporting steady supply and simplifying service.
Models and Technical Specifications
HQE Series | 50 Hz Specifications
Specification |
HQE-200 |
HQE-400 |
HQE-800 |
|---|---|---|---|
Motor Rating (HP) |
1/4 |
1/2 |
1 |
Power (W) |
200 |
400 |
800 |
Phase (Φ) |
Single-phase |
Single-phase |
Single-phase |
Voltage (V) |
220–240 |
220–240 |
220–240 |
Maximum Current (A) |
1.2–1.1 |
1.7–1.6 |
3.8–3.5 |
Rated Head (m) |
15 |
20 |
25 |
Maximum Head (m) |
25 |
28 |
35 |
Rated Flow (L/min) |
27 |
32 |
50 |
Maximum Flow (L/min) |
47 |
65 |
82 |
Port Connection |
Rp 1″ |
Rp 1″ |
Rp 1″ |
HQE Series | 60 Hz Specifications
Specification |
HQE-200 |
HQE-400 |
HQE-800 |
|---|---|---|---|
Motor Rating (HP) |
1/4 |
1/2 |
1 |
Power (W) |
200 |
400 |
800 |
Phase (Φ) |
Single-phase |
Single-phase |
Single-phase |
Voltage (V) |
100–120/200–240 |
100–120/200–240 |
100–120/200–240 |
Maximum Current (A) |
3.4–3.0/1.7–1.5 |
5.8–5.2/2.9–2.6 |
10.2–9.2/5.1–4.6 |
Rated Head (m) |
15 |
20 |
25 |
Maximum Head (m) |
24 |
28 |
35 |
Rated Flow (L/min) |
27 |
31 |
50 |
Maximum Flow (L/min) |
55 |
75 |
95 |
Port Connection |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Performance Curves and Dimensions
Performance Curves
50 Hz on the left and 60 Hz on the right. Select the image to enlarge it.
Dimensions
50 Hz at the top and 60 Hz at the bottom. Dimensions are in mm. Select the image to enlarge it.
HQF Series | Flow-Sensing Centrifugal Booster Pump

Flow sensing helps the pump respond to changing demand.
The HAITIMA HQF centrifugal booster pump uses a flow sensor and electronic control board to start and stop the pump. Dry-run shutdown and dual overheat protection help protect the equipment.
- Flow Sensing — Starts and stops the pump according to water demand.
- Equipment Protection — Includes dry-run shutdown and dual overheat protection.
- Status Indicators — LEDs make operating status easy to check.
- Low-Noise Operation — A centrifugal impeller helps keep operating noise low.
- Self-Priming Suction Lift — 6 m
HQF Key Features
Core Sensing and Control Technology
HQF combines flow sensing with integrated electronic control to respond to water demand and simplify servicing.
Models and Technical Specifications
HQF Series | 50 Hz Specifications
Specification |
HQF-200 |
HQF-400 |
HQF-800 |
|---|---|---|---|
Motor Rating (HP) |
1/4 |
1/2 |
1 |
Power (W) |
200 |
400 |
800 |
Phase (Φ) |
Single-phase |
Single-phase |
Single-phase |
Voltage (V) |
220–240 |
220–240 |
220–240 |
Maximum Current (A) |
1.2–1.1 |
1.7–1.6 |
3.8–3.5 |
Rated Head (m) |
15 |
20 |
25 |
Maximum Head (m) |
25 |
28 |
35 |
Rated Flow (L/min) |
27 |
32 |
50 |
Maximum Flow (L/min) |
47 |
65 |
82 |
Port Connection |
Rp 1″ |
Rp 1″ |
Rp 1″ |
HQF Series | 60 Hz Specifications
Specification |
HQF-200 |
HQF-400 |
HQF-800 |
|---|---|---|---|
Motor Rating (HP) |
1/4 |
1/2 |
1 |
Power (W) |
200 |
400 |
800 |
Phase (Φ) |
Single-phase |
Single-phase |
Single-phase |
Voltage (V) |
100–120/200–240 |
100–120/200–240 |
100–120/200–240 |
Maximum Current (A) |
3.4–3.0/1.7–1.5 |
5.8–5.2/2.9–2.6 |
10.2–9.2/5.1–4.6 |
Rated Head (m) |
15 |
20 |
25 |
Maximum Head (m) |
24 |
28 |
35 |
Rated Flow (L/min) |
27 |
31 |
50 |
Maximum Flow (L/min) |
55 |
75 |
95 |
Port Connection |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Performance Curves and Dimensions
Performance Curves
50 Hz on the left and 60 Hz on the right. Select the image to enlarge it.
Dimensions
50 Hz at the top and 60 Hz at the bottom. Dimensions are in mm. Select the image to enlarge it.
HPE Series | Electronic Pressure-Stabilizing Booster Pump

Responds to water demand for a steadier supply.
The HAITIMA HPE uses pressure and flow sensing to operate automatically as demand changes, providing reliable pressure boosting for everyday household water use.
- Dual-Sensor Control — Pressure and flow sensors detect changes in water demand.
- Reliable Operation — Electronic control and protective features support reliable operation.
- Easy Maintenance — Modular construction simplifies component inspection and replacement.
- Self-Priming Suction Lift — 9 m
HPE Key Features
Core Sensing and Control Technology
Integrated electronic control helps the booster pump respond to water demand, supporting steady supply and simplifying service.
Models and Technical Specifications
Specification |
HPE-200 |
HPE-300 |
HPE-400 |
HPE-600 |
HPE-800 |
|---|---|---|---|---|---|
Motor Rating (HP) |
1/4 |
1/3 |
1/2 |
3/4 |
1 |
Power (W) |
200 |
300 |
400 |
600 |
800 |
Phase (Φ) |
Single-phase |
Single-phase |
Single-phase |
Single-phase |
Single-phase |
Voltage (V) |
220~240 |
220~240 |
220~240 |
220~240 |
220~240 |
Maximum Current (A) |
1.2~1.1 |
1.5~1.4 |
1.7~1.6 |
3.0~2.8 |
3.8~3.5 |
Rated Head (m) |
11 |
12.5 |
14 |
15.5 |
17 |
Maximum Head (m) |
20 |
23.5 |
27 |
33 |
38 |
Rated Flow (L/min) |
26.5 |
31 |
38 |
45.5 |
53.5 |
Maximum Flow (L/min) |
52 |
56 |
64 |
75 |
85 |
Port Connection |
Rp 1″ |
Rp 1″ |
Rp 1″ |
Rp 1″ |
Rp 1″ |
Specification |
HPE-200 |
HPE-300 |
HPE-400 |
HPE-600 |
HPE-800 |
|---|---|---|---|---|---|
Motor Rating (HP) |
1/4 |
1/3 |
1/2 |
3/4 |
1 |
Power (W) |
200 |
300 |
400 |
600 |
800 |
Phase (Φ) |
Single-phase |
Single-phase |
Single-phase |
Single-phase |
Single-phase |
Voltage (V) |
100~120/200~240 |
100~120/200~240 |
100~120/200~240 |
100~120/200~240 |
100~120/200~240 |
Maximum Current (A) |
3.4~3.0/1.7~1.5 |
4.6~4.0/2.3~2.0 |
5.8~5.2/2.7~2.6 |
7.8~7.2/3.9~3.6 |
10.0~9.2/5.0~4.6 |
Rated Head (m) |
11 |
12.5 |
14 |
15.5 |
17 |
Maximum Head (m) |
21 |
26 |
31 |
36 |
41 |
Rated Flow (L/min) |
28 |
41 |
48 |
53.5 |
58 |
Maximum Flow (L/min) |
56 |
66 |
75 |
84 |
91 |
Port Connection |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Performance Curves and Dimensions
The curves show 50 Hz on the left and 60 Hz on the right. Head is in m and flow is in L/min. Dimensions are in mm. Check dimensions A and B for your model.
HPF Series | Flow-Sensing Electronic Booster Pump

Flow sensing helps the pump respond to changing demand.
The HAITIMA HPF uses flow sensing to control start and stop and includes dry-run shutdown. Integrated electronic control responds to water demand, and modular construction simplifies maintenance.
- Flow Sensing — Starts and stops the pump according to water demand.
- Dry-Run Shutdown — Stops the pump when water is unavailable to help protect the equipment.
- Easy Maintenance — Modular construction simplifies component inspection and replacement.
- Self-Priming Suction Lift — 9 m
HPF Key Features
Core Sensing and Control Technology
HPF combines flow sensing with integrated electronic control to respond to water demand and simplify servicing.
Models and Technical Specifications
Specification |
HPF-200 |
HPF-300 |
HPF-400 |
HPF-600 |
HPF-800 |
|---|---|---|---|---|---|
Motor Rating (HP) |
1/4 |
1/3 |
1/2 |
3/4 |
1 |
Power (W) |
200 |
300 |
400 |
600 |
800 |
Phase (Φ) |
Single-phase |
Single-phase |
Single-phase |
Single-phase |
Single-phase |
Voltage (V) |
220~240 |
220~240 |
220~240 |
220~240 |
220~240 |
Maximum Current (A) |
1.2~1.1 |
1.5~1.4 |
1.7~1.6 |
3.0~2.8 |
3.8~3.5 |
Rated Head (m) |
11 |
12.5 |
14 |
15.5 |
17 |
Maximum Head (m) |
20 |
23.5 |
27 |
33 |
38 |
Rated Flow (L/min) |
26.5 |
31 |
38 |
45.5 |
53.5 |
Maximum Flow (L/min) |
52 |
56 |
64 |
75 |
85 |
Port Connection |
Rp 1″ |
Rp 1″ |
Rp 1″ |
Rp 1″ |
Rp 1″ |
Specification |
HPF-200 |
HPF-300 |
HPF-400 |
HPF-600 |
HPF-800 |
|---|---|---|---|---|---|
Motor Rating (HP) |
1/4 |
1/3 |
1/2 |
3/4 |
1 |
Power (W) |
200 |
300 |
400 |
600 |
800 |
Phase (Φ) |
Single-phase |
Single-phase |
Single-phase |
Single-phase |
Single-phase |
Voltage (V) |
100~120/200~240 |
100~120/200~240 |
100~120/200~240 |
100~120/200~240 |
100~120/200~240 |
Maximum Current (A) |
3.4~3.0/1.7~1.5 |
4.6~4.0/2.3~2.0 |
5.8~5.2/2.7~2.6 |
7.8~7.2/3.9~3.6 |
10.0~9.2/5.0~4.6 |
Rated Head (m) |
11 |
12.5 |
14 |
15.5 |
17 |
Maximum Head (m) |
21 |
26 |
31 |
36 |
41 |
Rated Flow (L/min) |
28 |
41 |
48 |
53.5 |
58 |
Maximum Flow (L/min) |
56 |
66 |
75 |
84 |
91 |
Port Connection |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Performance Curves and Dimensions
The curves show 50 Hz on the left and 60 Hz on the right. Head is in m and flow is in L/min. Dimensions are in mm. Check dimensions A and B for your model.
HPL Series | Water Transfer Pump with Dual Protection

Designed for general water transfer and supply. This series has no dry-run shutdown. Verify the water source and operating conditions before installation.
- Easy Maintenance — Modular construction simplifies component inspection and replacement.
- Self-Priming Suction Lift — 9 m
HPL Key Features
Core Control Technology
Models and Technical Specifications
Specification |
HPL-200 |
HPL-300 |
HPL-400 |
HPL-600 |
HPL-800 |
|---|---|---|---|---|---|
Motor Rating (HP) |
1/4 |
1/3 |
1/2 |
3/4 |
1 |
Power (W) |
200 |
300 |
400 |
600 |
800 |
Phase (Φ) |
Single-phase |
Single-phase |
Single-phase |
Single-phase |
Single-phase |
Voltage (V) |
220~240 |
220~240 |
220~240 |
220~240 |
220~240 |
Maximum Current (A) |
1.2~1.1 |
1.5~1.4 |
1.7~1.6 |
3.0~2.8 |
3.8~3.5 |
Rated Head (m) |
11 |
12.5 |
14 |
15.5 |
17 |
Maximum Head (m) |
20 |
23.5 |
27 |
33 |
38 |
Rated Flow (L/min) |
26.5 |
31 |
38 |
45.5 |
53.5 |
Maximum Flow (L/min) |
52 |
56 |
64 |
75 |
85 |
Port Connection |
Rp 1″ |
Rp 1″ |
Rp 1″ |
Rp 1″ |
Rp 1″ |
Specification |
HPL-200 |
HPL-300 |
HPL-400 |
HPL-600 |
HPL-800 |
|---|---|---|---|---|---|
Motor Rating (HP) |
1/4 |
1/3 |
1/2 |
3/4 |
1 |
Power (W) |
200 |
300 |
400 |
600 |
800 |
Phase (Φ) |
Single-phase |
Single-phase |
Single-phase |
Single-phase |
Single-phase |
Voltage (V) |
100~120/200~240 |
100~120/200~240 |
100~120/200~240 |
100~120/200~240 |
100~120/200~240 |
Maximum Current (A) |
3.4~3.0/1.7~1.5 |
4.6~4.0/2.3~2.0 |
5.8~5.2/2.7~2.6 |
7.8~7.2/3.9~3.6 |
10.0~9.2/5.0~4.6 |
Rated Head (m) |
11 |
12.5 |
14 |
15.5 |
17 |
Maximum Head (m) |
21 |
26 |
31 |
36 |
41 |
Rated Flow (L/min) |
28 |
41 |
48 |
53.5 |
58 |
Maximum Flow (L/min) |
56 |
66 |
75 |
84 |
91 |
Port Connection |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Rp 1″/NPT 1″ |
Performance Curves and Dimensions
The curves show 50 Hz on the left and 60 Hz on the right. Head is in m and flow is in L/min. Dimensions are in mm. Check dimensions A and B for your model.

HAITIMA|HVM SERIES
HVM Series | Vertical Multistage Centrifugal Pumps
Designed for commercial pressure boosting and industrial water supply.
Stainless steel impellers and diffusers are paired with a cartridge mechanical seal. Depending on the model, flanged, grooved, Rp-threaded or NPT-threaded connections are available.
Key Design Features
- Connection Options — Choose flanged, grooved, Rp-threaded or NPT-threaded connections according to model and piping requirements.
- Cartridge Mechanical Seal — Simplifies seal replacement.
- Stainless Steel Impellers and Diffusers — Confirm materials for the selected model and liquid.
- Totally Enclosed Fan-Cooled Motor — Confirm motor operating conditions for the selected model.
Applications
Series Specifications
Item |
Series Data |
|---|---|
Maximum Flow |
150 m³/h |
Maximum Head |
277 m |
Liquid Temperature |
−15 to +120 °C |
Material Options |
AISI 304/316 |
Maximum flow and head are separate series limits. Confirm the duty point, liquid temperature and materials for the selected model.
HVM Selection Enquiries
Please provide the required flow, head, power frequency, liquid type and temperature, and connection type.
Catalogue Downloads
HP Series Booster Pump Documents
Download Catalogue (Chinese PDF)Download English Catalogue (PDF)











